PATIENT MONITOR SPO2 NIBP ECG TEMP PRINTER VIRGO
Available Options | |
---|---|
Enter qty and post code to calculate shipping:
Anesthesia Patient Monitor
Anesthesia Patient Monitor
- 12.1” colour TFT LCD Screen
- Suitable for adult, pediatric & neonatal patients
- Flexible parameters configuration for different clinical environments
- Standard Configuration 3 Lead ECG, HR, RESP, NIBP, Spo2, 2 Temp, PR
- Accurate Alarming System
- Big Font Mode
- 8 Hours holographic waveform review
- 120 hour graphical & tabular trend review with customisable size & colour settings
- Rechargeable high capacity Li-ion battery
Optional
- Thermal printer, Trolley, Wall Mount, Skin Temp,
Optional mobile stand available as pictured $495+GST
(NORNVIPR)
Display
12.1″ color TFT screen
Resolution: 800*600 dpi
Number of traces: 8 waveforms
Indicator
Power indicator light
Battery indicator light
Battery
Rechargeable lithium battery
I/O
LAN: 1 standard RJ45 Port
WLAN: IEEE802.11 b/g/n
USB: 2 USB connectors
SO: 1 SO card Socket
VGA: 1 standard color VGA monitor connector
Output: 1 standard connector for Nurse Call, Defib Sync Analog Output
Recorder (Optional)
Built-in, thermal dot array
Waveform: 3 channels
Paper width: 50mm
Print speed: 12.5 mm/s, 25mm/s, 50mm/s
ECG
Lead Type: 3-lead, 5-lead, 12-lead
ECG waveform: 2 channels, 7 channels, 12 channels
Gain selection: x0.25, x0.5; x1; x2
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Filter: Diagnostic mode: 0.05-150Hz
Monitoring mode: 0.5-40 Hz
Surgery mode: 1-20Hz
Notch: 50Hz, 60Hz
Heart Rate range: Adult: 15-300bpm;
Pediatric/ Neonate: 15-350bpm;
Accuracy: ±1 bpm or ±1 %, whichever is greater
Resolution: ±1 bpm
Respiration
Method: Trans-thoracic impedance
Operation modes: Auto/ Manual
Measurement range: Adult: 0-120 bpm;
Neonate/Pediatric: 0-150 bpm
Apnea alarm delay: 1 Os, 15s, 20s, 25s, 30s, 35s, 40s
Apnea Alarm: Selectable
Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s
Sp02
Measurement range: 0-100%
Resolution: 1%
Accuracy: ±2% (70-100% Adult/Pediatric);
±3% (70-100% Neonate);
0-69% unspecified
Refreshing rate: 1s
Masimo SET®
SP02(0ptional)
Accuracy: ±2% (70-100% Adult/Pediatric, non-motion,low perfusion);
±3% (70-100% Neonate, non-motion);
±3% (70-100% motion);
0-69% unspecified
Pulse Rate
Range: 0-254 bpm
Resolution: 1 bpm
Accuracy: ±3bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1s
NIBP
Method: Automatic oscillometric
Operation modes: Manual/Auto I STAT
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range:
Range of systolic pressure: Adult Mode 40-270 mmHg
Pediatric Mode 40-200 mmHg
Neonatal Mode 40 – 135 mmHg
Range of diastolic pressure: Adult Mode 10-210 mmHg
Pediatric Mode 10 – 150 mmHg
Neonatal Mode 10-100 mmHg
Range of mean pressure: Adult Mode 20- 230mmHg
Pediatric Mode 20- 165mmHg
Neonatal Mode 20- 110mmHg
Accuracy: Max mean error: ±5 mmHg
Measurement Interval: 1 ,2,3,4,5, 10, 15,30,60,90, 120,180,240,
480minutes
Over-pressure protection: Double safety protection
Cuff pressure range: 0-280 mmHg
Resolution: 1 mmHg
Temperature
Accuracy: ±0.1 “C or ±0.2 “F (without probe)
Measurement range: 0-50″C (32 to 122 “F)
Channel: Two-channels
Resolution: 0.1 “C
Parameters: T1 , T2 and TD
IBP (Optional)
Channel: 2-channel
Measurement types: Systolic, Diastolic, Mean
Range:OmmHg-300mmHg
Resolution: 1 mmHg
Accuracy: ±2% or ±1 mmHg, whichever is greater (without sensor)
Sensitivity: 5uV/mmHgN
Impedance range: 300 to 3000
Operation Environment
Power: AC100-250V, 50/60Hz
Temperature: 0 -40″C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate
SKU | NORNVIPR |
Brand | Mediana |
Shipping Weight | 4.0700kg |
Shipping Width | 0.232m |
Shipping Height | 0.354m |
Shipping Length | 0.282m |
Shipping Cubic | 0.023160000m3 |
Unit Of Measure | ea |
Be The First To Review This Product!
Help other RG Medical Supplies - NSW users shop smarter by writing reviews for products you have purchased.